CT220 XtremeSense TMR Contactless Current Sensors

Allegro MicroSystems CT220 XtremeSense™ TMR Contactless Current Sensors high-linearity and high-resolution contactless modules with patented XtremeSense TMR technology. These sensors measure the magnetic field of the current flowing through a busbar or printed circuit board (PCB) trace and convert it to an analog output voltage that represents the field and current. These contactless current sensors provide a typical total output error of ±0.5% while the sensing field (current) is as low as 5mA. The series offers a 2.7V to 5.5V supply voltage range and a 1.2mA supply current rating in a five-lead SOT23 package. Allegro MicroSystems CT220 XtremeSense TMR Contactless Current Sensors feature inherently high isolation, making them an ideal solution for applications requiring product safety compliance.

結果: 13
選擇 圖像 零件編號 製造商 說明 規格書 供貨情況 定價 (TWD) 基於數量按單價篩選表中結果。 數量 RoHS ECAD模型 傳感器類型 回應時間 準確性 頻率範圍 工作電源電壓 輸出類型
Allegro MicroSystems 板上安裝電流感測器 CT220BMC-HS5 2,133庫存量
最少: 1
倍數: 1
: 3,000

Current Sense 20 us 0.5 % 200 kHz 2.7 V to 5.5 V Analog
Allegro MicroSystems 板上安裝電流感測器 XtremeSense High Linearity, High-Resolution Contact Current Sensor, 6-lead DFN, +/-1.5 mT, High Accuracy, H-Temp 2,753庫存量
最少: 1
倍數: 1
: 3,000

Current Sense 20 us 0.5 % 200 kHz 2.7 V to 5.5 V Analog
Allegro MicroSystems 板上安裝電流感測器 CT220RMC-IS5 2,317庫存量
最少: 1
倍數: 1
: 3,000

Current Sense 20 us 0.5 % 200 kHz 2.7 V to 5.5 V Analog
Allegro MicroSystems 板上安裝電流感測器 CT220RMC-HS5 402庫存量
最少: 1
倍數: 1
: 3,000

Current Sense 20 us 0.5 % 200 kHz 2.7 V to 5.5 V Analog
Allegro MicroSystems 板上安裝電流感測器 XtremeSense High Linearity, High-Resolution Contact Current Sensor, 6-lead DFN, +/-15 mT, High Accuracy, H-Temp 300庫存量
最少: 1
倍數: 1
: 3,000

Current Sense 20 us 0.5 % 200 kHz 2.7 V to 5.5 V Analog
Allegro MicroSystems 板上安裝電流感測器 CT220FMC-IS5
17,945預期2026/4/13
最少: 1
倍數: 1
: 3,000

Current Sense 20 us 0.5 % 200 kHz 2.7 V to 5.5 V Analog
Allegro MicroSystems 板上安裝電流感測器 CT220BMC-IS5
3,000預期2026/5/18
最少: 1
倍數: 1
: 3,000

Current Sense 20 us 0.5 % 200 kHz 2.7 V to 5.5 V Analog
Allegro MicroSystems 板上安裝電流感測器 CT220BMV-IS5
3,000預期2026/5/25
最少: 1
倍數: 1
: 3,000

Current Sense 20 us 0.5 % 200 kHz 2.7 V to 5.5 V Analog
Allegro MicroSystems 板上安裝電流感測器 CT220RMV-IS5
3,000預期2026/5/18
最少: 1
倍數: 1
: 3,000

Current Sense 20 us 0.5 % 200 kHz 2.7 V to 5.5 V Analog
Allegro MicroSystems 板上安裝電流感測器 CT220FMC-HS5 無庫存前置作業時間 24 週
最少: 18,000
倍數: 18,000
: 3,000

Current Sense 20 us 0.5 % 200 kHz 2.7 V to 5.5 V Analog
Allegro MicroSystems 板上安裝電流感測器 CT220FMV-HS5 無庫存前置作業時間 24 週
最少: 18,000
倍數: 18,000
: 3,000

Current Sense 20 us 0.5 % 200 kHz 2.7 V to 5.5 V Analog
Allegro MicroSystems 板上安裝電流感測器 CT220PMC-HS5 無庫存前置作業時間 24 週
最少: 18,000
倍數: 18,000
: 3,000

Current Sense 20 us 0.5 % 200 kHz 2.7 V to 5.5 V Analog
Allegro MicroSystems 板上安裝電流感測器 XtremeSense High Linearity, High-Resolution Contactless Current Sensor, 6-lead DFN, +/-10 mT, Very High Accuracy, I-Temp 暫無庫存