Bourns HCTSM151207FAL High Clearance/Creepage Transformer

Bourns HCTSM151207FAL High Clearance and Creepage Transformer provides reinforced insulation with a working voltage up to 1500VDC. This Bourns push-pull isolation transformer is AEC-Q200 compliant and automotive-grade for high reliability. The HCTSM151207FAL features a creepage/clearance distance of 15mm+ and a 7640VAC Hi-Pot. This high clearance and creepage transformer is designed for isolation power supplies using Texas Instruments SN6501 and SN6505B transformer drivers.

Features

  • Up to 1500VDC working voltage
  • 7640VAC, 1mA, 2s Hi-Pot
  • Reinforced insulation
  • >15mm clearance/creepage distance
  • Overvoltage Category II, Pollution Degree 2, up to 2km above sea level
  • IEC 60664-1:2007, IEC/UL 62368-1:2018, and UL 62368-1:2021
  • AEC-Q200 compliant
  • RoHS compliant

Applications

  • Energy storage systems (ESS)
  • High-voltage/high-current DC meters
  • CAN interface digital input modules
  • RS-485 and RS-232 isolation
  • Isolation power supplies using TI SN6501 and SN6505B

Specifications

  • 400µH minimum primary inductance
  • 70µH maximum leakage inductance
  • -40°C to +125°C operating temperature range
  • Moisture Sensitivity Level (MSL) 1
  • DC resistance (DCR)
    • 1.5Ω maximum (1-3 turns ratio)
    • 1.0Ω maximum (6-4 turns ratio)

Schematic

Schematic - Bourns HCTSM151207FAL High Clearance/Creepage Transformer

Dimensions

Mechanical Drawing - Bourns HCTSM151207FAL High Clearance/Creepage Transformer
發佈日期: 2026-02-27 | 更新日期: 2026-02-27