TMCS1123/TMCS1123-Q1 Hall-Effect Current Sensors

Texas Instruments TMCS1123/TMCS1123-Q1 Precision Hall-Effect Current Sensors are designed to address the need for highly accurate current measurements in high-voltage systems such as electric vehicle (EV) charging and solar energy. These galvanically isolated sensors offer up to 80ARMS at +25°C and robust reinforced isolation with 1100VDC reinforced working voltage and 5000VRMS withstand isolation voltage. The precision signal conditioning circuitry with built-in drift compensation achieves less than 1.75% maximum total error over temperature and lifetime with no system-level calibration, making the TMCS1123/TMCS1123-Q1 series a highly accurate solution throughout the system's lifetime. The devices can be used for AC and DC current measurements and offer a bandwidth of 250kHz. TI TMCS1123/TMCS1123-Q1 Precision Hall-Effect Current Sensors operate with a low voltage supply from 3V to 5.5V and come in an SOIC (DVG) 10-pin package. The TMCS1123-Q1 devices are AEC-Q100 qualified for automotive applications.

感測器的類型

變更類別視圖
結果: 31
選擇 圖像 零件編號 製造商 說明 規格書 供貨情況 定價 (TWD) 基於數量按單價篩選表中結果。 數量 RoHS
Texas Instruments 板機接口霍耳反應/磁性傳感器 3,637庫存量
最少: 1
倍數: 1
最大: 250
: 2,000

Texas Instruments 板機接口霍耳反應/磁性傳感器 1,858庫存量
最少: 1
倍數: 1
最大: 1,001
: 2,000

Texas Instruments 板機接口霍耳反應/磁性傳感器 1,993庫存量
最少: 1
倍數: 1
最大: 1,001
: 2,000

Texas Instruments 板機接口霍耳反應/磁性傳感器 1,922庫存量
最少: 1
倍數: 1
最大: 1,001
: 2,000

Texas Instruments 板機接口霍耳反應/磁性傳感器 1,641庫存量
最少: 1
倍數: 1
最大: 1,001
: 2,000

Texas Instruments 板機接口霍耳反應/磁性傳感器 1,531庫存量
最少: 1
倍數: 1
最大: 1,001
: 2,000

Texas Instruments 板機接口霍耳反應/磁性傳感器 1,844庫存量
最少: 1
倍數: 1
最大: 1,001
: 2,000

Texas Instruments 板機接口霍耳反應/磁性傳感器 1,995庫存量
最少: 1
倍數: 1
最大: 1,001
: 2,000

Texas Instruments 板機接口霍耳反應/磁性傳感器 1,993庫存量
最少: 1
倍數: 1
最大: 1,001
: 2,000

Texas Instruments 板機接口霍耳反應/磁性傳感器 1,496庫存量
最少: 1
倍數: 1
最大: 1,001
: 2,000

Texas Instruments 板機接口霍耳反應/磁性傳感器 1,349庫存量
最少: 1
倍數: 1
最大: 1,001
: 2,000

Texas Instruments 板機接口霍耳反應/磁性傳感器 1,989庫存量
最少: 1
倍數: 1
最大: 1,001
: 2,000

Texas Instruments 板機接口霍耳反應/磁性傳感器 1,956庫存量
最少: 1
倍數: 1
最大: 1,001
: 2,000

Texas Instruments 板機接口霍耳反應/磁性傳感器 1,921庫存量
最少: 1
倍數: 1
最大: 1,001
: 2,000

Texas Instruments 板機接口霍耳反應/磁性傳感器 1,905庫存量
最少: 1
倍數: 1
最大: 1,001
: 2,000

Texas Instruments 板上安裝電流感測器 +/-1300V reinforced isolation 80Arms 25 1,977庫存量
最少: 1
倍數: 1
最大: 1,001
: 2,000

Texas Instruments 板上安裝電流感測器 +/-1300V reinforced isolation 80Arms 25 1,899庫存量
最少: 1
倍數: 1

Texas Instruments 板上安裝電流感測器 +/-1300V reinforced isolation 80Arms 25 1,525庫存量
最少: 1
倍數: 1
: 2,000

Texas Instruments 板上安裝電流感測器 +/-1300V reinforced isolation 80Arms 25 1,715庫存量
最少: 1
倍數: 1
: 2,000

Texas Instruments 板上安裝電流感測器 +/-1300V reinforced isolation 80Arms 25 1,412庫存量
最少: 1
倍數: 1
: 2,000

Texas Instruments 板上安裝電流感測器 +/-1300V reinforced isolation 80Arms 25 1,522庫存量
最少: 1
倍數: 1
: 2,000

Texas Instruments 板上安裝電流感測器 +/-1300V reinforced isolation 80Arms 25 926庫存量
最少: 1
倍數: 1
: 2,000

Texas Instruments 板上安裝電流感測器 +/-1300V reinforced isolation 80Arms 25 1,592庫存量
最少: 1
倍數: 1
: 2,000

Texas Instruments 板上安裝電流感測器 +/-1300V reinforced isolation 80Arms 25 1,064庫存量
最少: 1
倍數: 1

Texas Instruments 板上安裝電流感測器 +/-1300V reinforced isolation 80Arms 25 1,007庫存量
最少: 1
倍數: 1